Case Study: VARIED RU Series 15kW/12kW Programmable DC Power Supplies for Automated PCB Burn-in Testing
Core Summary
For high-throughput PCB board burn-in testing, VARIED deployed a PLC-controlled automated aging system powered by 4 units of RU Series Programmable DC Power Supplies: two RU-150-40400 (15kW, 40V/400A) units and two RU-120-40300 (12kW, 40V/300A) units. The aging fixture accommodates 300 pcs of PCB boards (20 pcs per row) rated at 12V and 18V, running continuously at a full-load current exceeding 200A for 1 hour to verify batch production yield with high power redundancy and stability.
1. Project Background & DUT Specifications
• Industry: Electronic Manufacturing Services (EMS)
• Device Under Test (DUT): 12V and 18V PCB Boards
• Test Challenge: The manufacturer required a mass burn-in test solution capable of handling 300 PCBs simultaneously, integrating seamlessly with a factory PLC system, and sustaining continuous >200A full-load output without thermal drift or voltage drop.
2. Selected Test Equipment & System Configuration
To guarantee long-term reliability and ample current headroom, the system utilizes a 4-unit combination totaling 54kW and 1400A of rated capacity:
Model Rated Power Rated Output (V / A) Quantity Role in System
VARIED RU-150-40400 15kW 40V / 400A 2 Units High-current DC supply for mass aging channels
VARIED RU-120-40300 12kW 40V / 300A 2 Units High-current DC supply for mass aging channels
• System Integration: Connected to the centralized PLC system via built-in industrial communication interfaces for automated remote control and monitoring.
• Actual Operating Status: Regulated 12V / 18V DC output, continuous full-load operation with total current >200A.
3. Core Power Supply Requirements
• PLC Automation Integration: Built-in communication interface enabling centralized PLC control, automated test sequencing, and real-time status feedback.
• Dual-Voltage Compatibility: High-precision 12V and 18V output to accommodate two distinct PCB specifications on the same line.
• High Current & Power Redundancy: Delivering >200A continuous load current backed by 300A–400A per-unit capacity to prevent power supply overload during mass aging.
• Continuous Thermal Stability: Industrial-grade cooling and circuit design to sustain uninterrupted 1-hour full-load burn-in cycles.
4. Standardized Burn-in Test Procedure
• Step 1 (System Handshaking): Connect the 4 RU series power supplies to the PLC system and establish communication handshaking for centralized control.
• Step 2 (DUT Loading): Load 300 pcs of PCB boards onto the burn-in test fixture arranged at 20 pcs per row.
• Step 3 (Power-On & Full-Load Aging): Trigger the power supplies via PLC to output 12V or 18V, operating at full DUT load with a total current exceeding 200A.
• Step 4 (Continuous Burn-in): Maintain stable, uninterrupted DC power output for a standard 1-hour aging cycle.
• Step 5 (Yield Inspection): Power down the system, inspect the 300 PCB boards, and calculate the production batch yield.
5. Solution Advantages & Customer Value
• ✅ Seamless Production Line Integration: Communication-ready architecture allows effortless PLC connection for fully automated aging workflows.
• ✅ High-Throughput Batch Efficiency: Synchronous burn-in of 300 PCBs per 1-hour cycle significantly reduces per-unit testing time.
• ✅ Generous Current Headroom: Combining 400A (15kW) and 300A (12kW) units easily handles >200A loads while keeping power supplies cool and stress-free.
• ✅ Comprehensive DUT Protection: Built-in Over-Voltage (OVP), Over-Current (OCP), and Over-Temperature Protection (OTP) safeguard high-density PCB batches during continuous testing.
6. Frequently Asked Questions (FAQ)
Q1: How are the power supplies controlled in this PCB burn-in system?
A: All four VARIED RU series power supplies feature built-in communication interfaces, allowing them to be directly integrated into and centrally controlled by the factory's PLC system.
Q2: What is the sample capacity and burn-in duration per test cycle?
A: The test fixture holds 300 pcs of PCBs (arranged 20 pcs per row) per batch, undergoing a continuous 1-hour full-load power-on aging test.
Q3: Why use 15kW (400A) and 12kW (300A) models when the total load current is just over 200A?
A: Utilizing high-current 300A and 400A models provides substantial power redundancy and allows multi-zone power distribution across the 300 PCBs, ensuring minimal voltage drop, lower thermal stress, and extended equipment lifespan during 24/7 factory operation.