I-Feeder Technologies

I-Feeder Technologies Precision Plant Nutrition Dosing Systems using machine learning, Smart Software and collaborations

Venturi vs Positive Displacement Pump vs Fertilizer Tank: Which fertigation system is actually right for your pivot?Ever...
30/07/2026

Venturi vs Positive Displacement Pump vs Fertilizer Tank: Which fertigation system is actually right for your pivot?
Every farm, every crop and every irrigation system is different. That’s why we’ve put together an objective comparison of the three most common fertigation methods used on centre pivots.

We compare:
● How each system works
● Where each system performs best
● The strengths and limitations of each
● Which growers and applications each system is best suited for

The biggest mistake is comparing price instead of performance.

A Venturi injector, a positive displacement pump and a fertilizer tank all have their place—but they deliver very different levels of accuracy, consistency, control and labour requirements.

There is no universal winner. There is only the system that best matches your crop, your management style and your production goals.

Compare apples with apples. Then make an informed decision.

www.ifeederglobal.com
[email protected]
+27 83 457 9991

🔧 DIAPHRAGMS CONTINUOUSLY TEARING? Ask the right questions before replacing another one.We recently investigated an I-Fe...
15/07/2026

🔧 DIAPHRAGMS CONTINUOUSLY TEARING? Ask the right questions before replacing another one.

We recently investigated an I-Feeder PD pump where the diaphragm was repeatedly tearing, while two identical pumps installed alongside it continued operating without any issues.

That immediately suggested the problem was not the pump, but something unique to that installation.

An important clue: the damaged diaphragm, shown in the photo, was on the suction side of the fertigation pump.

In our experience, 9 out of 10 times this points to a suction-side problem.

Common causes include:

* Blocked suction filters
* Fertiliser or chemical with a viscosity higher than the pump was designed for
* Improper mixing, allowing solids to remain in suspension
* Air entering the suction line
* Blowers being used instead of hydraulic mixers, introducing air into the product
* Suction lines that are too long or too small in diameter, creating excessive vacuum

In this particular case, the root cause turned out to be something different.

A spring-loaded non-return valve had been installed on the suction side. The valve was incorrectly specified for the application, and the internal O-rings had begun to disintegrate. Fragments of the O-rings partially blocked the valve, restricting product flow and creating excessive suction conditions. The result was repeated diaphragm failure.

The lesson?

Replacing diaphragms without finding the underlying cause usually leads to the next diaphragm failing as well.

Successful maintenance isn’t about changing parts—it’s about understanding why they failed.

Before replacing another diaphragm, ask:
✔️ Is the suction line unrestricted?
✔️ Is the product being mixed correctly?
✔️ Is air entering the system?
✔️ Are all valves suitable for the application?
✔️ Has anything changed since the problem started?

Finding the root cause saves downtime, reduces maintenance costs, and keeps your fertigation system operating reliably.

📧 [email protected]
🌐 www.ifeederglobal.com



I-Feeder Global – Your trusted partner in pivot fertigation and chemigation.

09/07/2026

01/07/2026

💧 The I-Feeder Dosing System accurately mixes and injects fertilizers, nutrients, or chemicals directly into your irrigation water — delivering consistent nutrition exactly where crops need it most: the root zone.

✔ Precise fertilizer dosing
✔ Reduced waste & input costs
✔ Stronger, more consistent crop growth
✔ Reliable and easy to operate

With 350+ installations across Namibia, Cherry Irrigation has the experience to install a system that works efficiently from day one.

  through centre pivots is not safe.Not when a   is simply connected to an irrigation line.Not when the injection rate i...
22/06/2026

through centre pivots is not safe.

Not when a is simply connected to an irrigation line.

Not when the injection rate is guessed.

Not when backflow prevention is ignored.

Not when the operator cannot verify what is being applied.

That may sound direct, but it is the truth.

fertigation only becomes safe when the system is properly engineered.

It is guesswork with a pump attached.

With the right design, centre pivot fertigation can be one of the most efficient ways to apply nutrients at scale.

But safety does not come from the word “fertigation”.

It comes from proper pump sizing, injection design, backflow prevention, chemical compatibility, calibration, flushing, and operator training.

At I-Feeder Global Dosing Systems, we believe pivot fertigation should be engineered — not improvised.

Read the full how to here:
https://www.ifeederglobal.com/blog/2026/6/22/fertigation-through-centre-pivots-is-it-safe

01/06/2026
28/03/2026

Address

14 St. Edmunds Close
London
NW87QS

Alerts

Be the first to know and let us send you an email when I-Feeder Technologies posts news and promotions. Your email address will not be used for any other purpose, and you can unsubscribe at any time.

Featured

Share